詳細
Part no.: YHHC-48B
System: computer controlled system
Standard dies: 16 sets of dies from 1/4’’ to 3’’
Voltage: 380V/50HZ; if other voltage required, please advise us.
Stock available: we have kept many types in stock, then we can ensure the fast delivery.
技術データ表
タイプ | YHHC-48B (computer system controlled) |
Crimping range | Φ6—φ76 4SP |
Motor | Y-4/4kw |
Voltage | 380V*50HZ |
Capacity of oil pump | 19L/min |
系統的圧力 | 30MPa |
Hydraulic oil | Winter :YB-N32 |
Summer :YB-N46 | |
Oil tank volume | 480×440×360mm3 |
L*W*H | 800×650×1350(mm) |
Crimping pressure | 903T |
当社のサービス
1.世界中に多くのエージェントがいるので、エージェントに連絡して製品を購入することができます
2.Technical support any time, Our engineer cellphone:
+86-15158322675
3.Warranty time 3years、機械が付いている保証書はあなたに一緒に。
4.ビデオを使用して、マシンの使用方法を学習します。
5. Door to door service, we are in charge of sending the machine to your office, after payment.fitting ferrule crimping machine
6.weはあなたの引くことおよび条件として機械を設計できます。 OEM
よくある質問
Trouble phenomena | Trouble reason | Eliminating method |
Machine has not action | Oil tank has not been filled with oil | Fill oil as per requirement |
Motor rotation direction is not correct | Regulate two phase lines | |
Electric trouble | Overhaul electric circuits | |
Scale is damaged | The scale is fastened on the oil cylinder end face by the screw | Regulate the scale as per the instruction to make scale to telescope freely |
Conductor at scale location is connected with scale | Anew connect the scale conductor to make it to be insulated from scale base | |
Electric trouble | Overhaul electric circuits and electric elements | |
Scale conductor cutting | Anew connect scale | |
System pressure is excessively low | Adjust buckling pressure-regulating valve | |
No buckling | The valve core of solenoid reversal valve is seizured by foreign matters | Dismount solenoid reversal valve, use gasoline to clean the valve core. |
Electric trouble | Overhaul electric circuits | |
Mould is not opened | Opening mould pressure is excessively low | Adjust opening mould pressure regulating valve |
Electric trouble | Overhaul electric circuits | |
Lubrication is poor | Smear grease on the working inclined face of mould base | |
Oil leakage | Joint is not tightened closely | Tighten the oil pipe joint |
Sealing washer is damaged. | Replace sealing washer |